COIN SELECTOR
HANDLING THE COIN JAM
If the coin
is not rejected even when the
RElECT
button is pressed. open the coin
chute
door and open the selector gate.
After removing the jammed coin, put a
normat
coin
in
and check
fo see that the
sclectcjr correctly
functions.
1 CLEANING THE COIN SELECTOR
The
coin selector
should be cleaned
once every 3 months. When cleaning,
follow
the procedure below:
@
Turn the power for the machine OFF. Open
the coin chute door.
@ Openthegateanddustoffbyusingasoft
brusll (made of wool, etc.).
@
Remove and clean
sruars
by using a soft
cl&
dipped in water or diluted chemical
detergent and then wrung.
@ Remove
the
CRADLE.
When removing the retaining ring
(E ring). be very careful
so
as
not IO bend
the shaft.
@
Remove stain from the shaft and pillow
portions by wiping off with a soft cloth, dc.
@ After wiping off as
per
@
above,
funher
apply
a
dry cloth, etc. to cause the coin
xkctor
to dry compktely.
0
STOP
IMPORTANI!
0
Never apply machine oil,
etc. to the Coin Selector.
0
After cleaning the Coin
Selector, insert a regular
coin in the normal
working status and
ensure that the Selector
correctly functions.
COIN INSERTION TEST
Once every month, when
performing
the
Coin SW
Test, simultaneously
check the
following:
0
Does the Coin Meter count satisfactorily?
0
Does the coin drop into the Cschbox
corrccrly?
0
Is the coin rejected when inserted while
keeping the Reject Button pressed down?
FIG.
10
a
\
CRADLE
FIG. 10 b
Page view 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 135 136